Guide For Inkbird Smart Controller C919

Sensors

Device

1. How to add devices

- Tap “+” button to enter the “Add Device” interface

- Input your Wi-Fi name and password

- Long press “UP” button on the device until its Wi-Fi symbol flashes

- Tap “Start” button and wait a few minutes

4. How to get your slaves

2. How to get your devices

3. How to delete your devices

- Pull down and then release

 Slide left and tap “delete” button

- In the “iDevice” interface, tap a master to enter the “Master” interface and get your slaves which are green.

5. Time mode

- Make your device unplugged in any sensor

- Select this device in the app and enter the “Graph” interface

- Tap “…” button, and set count down time for the device

6. Temperature mode

- Plug a temperature sensor in your device

- Select this device in the app and enter the “Graph” interface

- Tap “…” button, and set parameters for the device

 

Parameter Description:

CF: Celsius or Fahrenheit, default: Fahrenheit

CH: Cool or Heat, default: Heat

T1: Temperature 1, rang: -50~100°C/-50~210°F, default: 24°C/78°

T2: Temperature 2, rang: -50~100°C/-50~210°F, default: 24°C/78°

PT: Compressor delay time, rang: 0~10min

CA: Temperature calibration, rang: -9.9~9.9°C/-15~15°

Master-Slave Switch: If the switch is on, slaves of the master will be setted into temperature mode.

Add Tasks:
- Tap the row of task, enter the “Task Scheduler” interface
- Tap “+” button, enter the “Add Task” interface
- Set all parameters of task, then tap “Done” button

Delete Tasks

- Slide left and tap “delete” button

7.  Humidity mode

- Plug a humidity sensor in your device

- Select this device in the app and enter the “Graph” interface

- Tap “…” button, and set parameters for the device

 

 

Parameter Description:

HD: Humifity or Dehumidity

H1: Humidity 1, range: 1~99%RH, default: 60%RH

H2: Humidity 2, range: 1~99%RH, default: 60%RH

CA: Humidity calibration, range: -15~15%RH, default: 0%RH

8. Cooking mode

- Plug a cooking sensor in your device

- Select this device in the app and enter the “Graph” interface

- Tap “…” button, and set parameters for the device

 

Parameter Description:

CF: Celsius or Fahrenheit, default: Fahrenheit

AT: Alarm temperature, range: 30~250°C/86~482°F, default: 100°C/210°F

CT: Alarm temperature, range: 30~250°C/86~482°F, default: 100°C/210°F

TS: Cooking time, range: 0~999min, default: 0min